{"product_id":"ecos-2-5-command-station-6a","title":"ESU 50220 ECoS Command Station (6A)","description":"\u003ch3 data-end=\"263\" data-start=\"186\"\u003eESU ECoS 50220 Command Station – Powerful, Versatile, and User-Friendly\u003c\/h3\u003e\n\u003cp data-end=\"555\" data-start=\"265\"\u003eThe \u003cstrong data-end=\"287\" data-start=\"269\"\u003eESU ECoS 50220\u003c\/strong\u003e is the second generation of ESU’s highly successful ECoS command station. Combining cutting-edge digital technology with intuitive controls, a clear touchscreen interface, and outstanding versatility, the ECoS offers an exceptional balance of performance and value.\u003c\/p\u003e\n\u003cp data-end=\"1004\" data-start=\"557\"\u003eWith its large, high-resolution colour display, easy-to-use interface, and robust functionality, the ECoS sets the standard for modern digital command stations. Unlike many alternatives, it can be comfortably operated without a stylus, thanks to its large, clearly marked symbols and menus. Two integrated driving cabs, each with a motor-driven throttle knob and nine function keys, make operating your locomotives straightforward and enjoyable.\u003c\/p\u003e\n\u003chr data-end=\"1009\" data-start=\"1006\"\u003e\n\u003ch3 data-end=\"1029\" data-start=\"1011\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-end=\"1065\" data-start=\"1031\"\u003e\u003cstrong data-end=\"1063\" data-start=\"1031\"\u003eMulti-Protocol Compatibility\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"1302\" data-start=\"1066\"\u003e\n\u003cli data-end=\"1141\" data-start=\"1066\"\u003e\n\u003cp data-end=\"1141\" data-start=\"1068\"\u003eSupports \u003cstrong data-end=\"1123\" data-start=\"1077\"\u003eDCC, Märklin® Motorola®, Selectrix® and M4\u003c\/strong\u003e data protocols.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1191\" data-start=\"1142\"\u003e\n\u003cp data-end=\"1191\" data-start=\"1144\"\u003eFull compatibility with mfx® decoders via M4.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1302\" data-start=\"1192\"\u003e\n\u003cp data-end=\"1302\" data-start=\"1194\"\u003eRun almost any existing decoder with ease – ECoS unifies four major data protocols in one command station.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"1328\" data-start=\"1304\"\u003e\u003cstrong data-end=\"1326\" data-start=\"1304\"\u003eLocomotive Control\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"1505\" data-start=\"1329\"\u003e\n\u003cli data-end=\"1424\" data-start=\"1329\"\u003e\n\u003cp data-end=\"1424\" data-start=\"1331\"\u003eTwo integrated cabs with large throttle knobs and nine function keys (with LED indicators).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1505\" data-start=\"1425\"\u003e\n\u003cp data-end=\"1505\" data-start=\"1427\"\u003eControl up to \u003cstrong data-end=\"1472\" data-start=\"1441\"\u003e31 functions per locomotive\u003c\/strong\u003e via the touchscreen interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"1538\" data-start=\"1507\"\u003e\u003cstrong data-end=\"1536\" data-start=\"1507\"\u003eAccessory \u0026amp; Route Control\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"1836\" data-start=\"1539\"\u003e\n\u003cli data-end=\"1620\" data-start=\"1539\"\u003e\n\u003cp data-end=\"1620\" data-start=\"1541\"\u003eOperate up to \u003cstrong data-end=\"1598\" data-start=\"1555\"\u003e1,420 turnouts and magnetic accessories\u003c\/strong\u003e (DCC or Motorola®).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1699\" data-start=\"1621\"\u003e\n\u003cp data-end=\"1699\" data-start=\"1623\"\u003eGraphical route control allows you to group and operate turnouts together.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1836\" data-start=\"1700\"\u003e\n\u003cp data-end=\"1836\" data-start=\"1702\"\u003eAutomatic route activation via feedback contacts or keys, with support for \u003cstrong data-end=\"1804\" data-start=\"1777\"\u003es88 occupancy detectors\u003c\/strong\u003e and \u003cstrong data-end=\"1833\" data-start=\"1809\"\u003eECoSDetector modules\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"1861\" data-start=\"1838\"\u003e\u003cstrong data-end=\"1859\" data-start=\"1838\"\u003eShuttle Operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"1989\" data-start=\"1862\"\u003e\n\u003cli data-end=\"1989\" data-start=\"1862\"\u003e\n\u003cp data-end=\"1989\" data-start=\"1864\"\u003eAutomated shuttle train control – simply install a rail contact at each end of your track and let the ECoS handle the rest.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2023\" data-start=\"1991\"\u003e\u003cstrong data-end=\"2021\" data-start=\"1991\"\u003eIntegrated Power \u0026amp; Booster\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"2210\" data-start=\"2024\"\u003e\n\u003cli data-end=\"2136\" data-start=\"2024\"\u003e\n\u003cp data-end=\"2136\" data-start=\"2026\"\u003eBuilt-in booster provides ample power for most layouts – often eliminating the need for additional boosters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2210\" data-start=\"2137\"\u003e\n\u003cp data-end=\"2210\" data-start=\"2139\"\u003eIdeal for large-scale applications such as \u003cstrong data-end=\"2207\" data-start=\"2182\"\u003eGauge 1 and G layouts\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2238\" data-start=\"2212\"\u003e\u003cstrong data-end=\"2236\" data-start=\"2212\"\u003eAdvanced Programming\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"2589\" data-start=\"2239\"\u003e\n\u003cli data-end=\"2314\" data-start=\"2239\"\u003e\n\u003cp data-end=\"2314\" data-start=\"2241\"\u003eEasy-to-use programming track for reading and writing decoder settings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2402\" data-start=\"2315\"\u003e\n\u003cp data-end=\"2402\" data-start=\"2317\"\u003eLarge colour TFT screen displays clear, full-text information for effortless setup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2517\" data-start=\"2403\"\u003e\n\u003cp data-end=\"2517\" data-start=\"2405\"\u003ePre-installed \u003cstrong data-end=\"2447\" data-start=\"2419\"\u003eRailCom® global detector\u003c\/strong\u003e recognises RailCom®-compatible decoders directly on the main track.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2589\" data-start=\"2518\"\u003e\n\u003cp data-end=\"2589\" data-start=\"2520\"\u003eFeedback of turnout positions possible via \u003cstrong data-end=\"2586\" data-start=\"2563\"\u003eSwitchPilot modules\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2620\" data-start=\"2591\"\u003e\u003cstrong data-end=\"2618\" data-start=\"2591\"\u003eEcoSlink High-Speed Bus\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"2738\" data-start=\"2621\"\u003e\n\u003cli data-end=\"2738\" data-start=\"2621\"\u003e\n\u003cp data-end=\"2738\" data-start=\"2623\"\u003eBuilt-in \u003cstrong data-end=\"2644\" data-start=\"2632\"\u003eEcoSlink\u003c\/strong\u003e (CAN-based) system for fast, reliable communication with accessories and expansion modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2774\" data-start=\"2740\"\u003e\u003cstrong data-end=\"2772\" data-start=\"2740\"\u003eExpandability \u0026amp; Connectivity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"2906\" data-start=\"2775\"\u003e\n\u003cli data-end=\"2832\" data-start=\"2775\"\u003e\n\u003cp data-end=\"2832\" data-start=\"2777\"\u003eIntegrated network port for connection to a computer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2906\" data-start=\"2833\"\u003e\n\u003cp data-end=\"2906\" data-start=\"2835\"\u003eEnables software updates, external control, and future expandability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"2911\" data-start=\"2908\"\u003e\n\u003ch3 data-end=\"2939\" data-start=\"2913\"\u003eWho is the ECoS For?\u003c\/h3\u003e\n\u003cul data-end=\"3568\" data-start=\"2941\"\u003e\n\u003cli data-end=\"3111\" data-start=\"2941\"\u003e\n\u003cp data-end=\"3111\" data-start=\"2943\"\u003e\u003cstrong data-end=\"2956\" data-start=\"2943\"\u003eBeginners\u003c\/strong\u003e: A straightforward entry into digital control. The large touchscreen, plain-text menus, and built-in help function make the ECoS remarkably easy to use.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3363\" data-start=\"3112\"\u003e\n\u003cp data-end=\"3363\" data-start=\"3114\"\u003e\u003cstrong data-end=\"3139\" data-start=\"3114\"\u003eExperienced modellers\u003c\/strong\u003e: Ideal for those upgrading from another digital system. With route and shuttle programming, advanced decoder programming, and the EcoSniffer interface, you can integrate existing equipment and expand your control options.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3568\" data-start=\"3364\"\u003e\n\u003cp data-end=\"3568\" data-start=\"3366\"\u003e\u003cstrong data-end=\"3391\" data-start=\"3366\"\u003eLarge-scale operators\u003c\/strong\u003e: With its powerful built-in booster, the ECoS is particularly well-suited to \u003cstrong data-end=\"3494\" data-start=\"3469\"\u003eGauge 1 and G layouts\u003c\/strong\u003e, allowing multiple trains to run simultaneously without extra boosters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ACCUE","offers":[{"title":"Default Title","offer_id":51674159776057,"sku":"50220","price":589.94,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0963\/7914\/2457\/files\/Ecos_1-2_web.jpg?v=1778519507","url":"https:\/\/heljan.com\/products\/ecos-2-5-command-station-6a","provider":"Heljan.com","version":"1.0","type":"link"}